True RMS multimeter with data logging, and software
- Large dot-matrix display
- Log function with TrendCapture
- Multiple readings per display
- "I" information button
- PC interfa ce for data transfer
- Low-pass filter for measurements on motor drives
- LoZ - low-impedance function
- Range of 50 O for measuring motor windings and measuring low
Reference | FLUKE-289/FVF |
---|---|
EAN code | 02004153995440 |
Brand | FLUKE |
Data sheet | FLUKE-289.pdf |
While stocks last | No |
True RMS multimeter FLUKE-289 with software
Datalogging and trend capture
The FLUKE-289 True RMS multimeter allows you to perform accurate and reliable measurements. This multimeter is equipped with a datalogging and trend capture function, which allows you to capture measurement values and analyze trends. This makes it easy to detect and solve problems.
With low pass filter
This multimeter is also equipped with a low pass filter, which allows you to make accurate measurements on motor drives. It also has a low impedance function (LoZ) and a range of 50 Ohms, allowing you to measure motor windings and perform low measurements.
Large dot matrix display
The large dot matrix display of the FLUKE-289 multimeter provides a clear and organized display of the measurement results. This allows you to quickly and easily read the necessary information.
Log function with TrendCapture
The log function with TrendCapture of the FLUKE-289 multimeter allows you to capture measurement values over a certain period of time. This allows you to identify and analyze trends and patterns in the measurement results. This helps you to detect problems and take the appropriate measures.
Multiple measurement values per display
The FLUKE-289 multimeter allows you to display multiple measurement values on the display at the same time. This provides an efficient and organized display of the measurement results, allowing you to quickly and easily read the necessary information.
"I" information button for convenient integrated help
The FLUKE-289 multimeter is equipped with a convenient "I" information button, which provides direct access to integrated help. This allows you to quickly and easily retrieve information about the different functions and settings of the multimeter.
PC interface for easy data transfer
The FLUKE-289 multimeter is equipped with a PC interface, which allows you to easily transfer measurement data to your computer. This allows you to save, analyze, and share the measurement results with others. This provides an efficient and organized way of working. The software is included.
Specifications: Fluke 289 TRMS Industrial Logging Multimeter with TrendCapture
Specifications | ||
Function | ||
DC volts | Range / resolution | 50.000 mV, 500.00 mV, 5.0000 V, 50.000 V, 500.00 V, 1000.0 V |
Basic accuracy | 0.025% | |
AC volts | Range / resolution | 50.000 mV, 500.00 mV, 5.0000 V, 50.000 V, 500.00 V, 1000.0 V |
Basic accuracy | 0.4% (True-RMS) | |
DC current | Range / resolution | 500.00 μA, 5000.0 μA, 50.000 mA, 400.00 mA, 5.0000 A, 10.000 A |
Basic accuracy | 0.05% | |
AC current | Range / resolution | 500.00 μA, 5000.0 μA, 50.000 mA, 400.00 mA, 5.0000 A, 10.000 A |
Basic accuracy | 0.6% (True-RMS) | |
Temperature (excluding probe) | Range / resolution | -200.0°C to 1350.0°C (-328.0°F to 2462.0°F) |
Basic accuracy | 1.0% | |
Resistance | Range / resolution | 50.000 Ω, 500.00 Ω, 5.0000 kΩ, 50.000 kΩ, 500.00 kΩ, 5.0000 MΩ, 50.00 MΩ, 500.0 MΩ |
Basic accuracy | 0.05% | |
Capacitance | Range / resolution | 1.000 nF,10.00 nF 100.0 nF, 1.000 μF, 10.00 μF, 100.0 μF, 1000 μF, 10.00 mF, 100 mF |
Basic accuracy | 1.0% | |
Frequency | Range / resolution | 99.999 Hz, 999.99 Hz, 9.9999 kHz, 99.999 kHz, 999.99 kHz |
Basic accuracy | 0.005% | |
Connectivity | Optional infrared connector via Fluke ir3000 FC | |
General Specifications | ||
Maximum voltage between any terminal and earth ground | 1000 V | |
Battery type | 6 AA alkaline batteries, IECLR6 | |
Battery life | 100 hours minimum, 200 hours in logging mode | |
Temperature | Operating | -20°C to 55°C |
Storage | -40°C to 60°C | |
Relative humidity | 0 to 90% (0 to 37°C), 0 to 65% (37°C to 45°C), 0 to 45% (45°C to 55°C) | |
Electromagnetic compatibility | EMC EN61326–1 | |
Vibration | Random vibration per MIL-PRF-28800F Class 2 | |
Shock | 1 meter drop per IEC/EN 61010–1 3rd Edition | |
Size (H x W x L) | 22.2 x 10.2 x 6 cm (8.75 x 4.03 x 2.38 in) | |
Weight | 870.9 g (28 oz) | |
Multiple on screen displays | Yes | |
True-RMS AC bandwidth | 100 kHz | |
dBV/dBm | Yes | |
DC mV resolution | 1 μV | |
Megohm range | Up to 500 MΩ | |
Conductance | 50.00 nS | |
Continuity beeper | Yes | |
Battery/fuse access | Yes/Yes | |
Elapse time clock | Yes | |
Time of day clock | Yes | |
Min-max-avg | Yes | |
Duty cycle | Yes | |
Pulse width | Yes | |
Isolated optical interface | Yes | |
Auto/touch hold | Yes | |
Reading memory | Yes | |
Log to PC | Yes | |
Interval/event logging | Yes | |
Logging memory | Up to 15,000 readings | |
Wireless connectivity (optional) | Yes |
* Ondanks een zeer uitgebreid stocksysteem, is het mogelijk dat de voorraadstatus niet overeenstemt met de actuele voorraad. Aarzel niet ons te contacteren, indien u zekerheid wenst over de beschikbaarheid.
** De weergegeven foto bij de producten kan verschillen van het eigenlijke product.