Multimeter with Temperature and Microamps HVAC

Reference
FLUKE-116EUR
Swipen voor 3 additionele foto's
€405.35 €335.00
13 in stock
Details
The 116 is for heating, ventilation and air conditioning (HVAC) engineers. It includes temperature measurement and microamp current ranges to quickly troubleshoot HVAC problems.
More Information
More Information
Reference FLUKE-116EUR
EAN code 02025680161375
Manufacturer FLUKE
Brand FLUKE
Promotion valid untill Dec 31, 2023
Data sheet FLUKE-116.pdf
Technical sheet FLUKE-110-series.pdf
While stocks last No
Technical specifications

Fluke 116 Multimeter - HVAC

Fluke 116 Multimeter - HVAC

The ideal multimeter for HVAC technicians

The Fluke 116 Multimeter is specifically designed for heating, ventilation, and air conditioning equipment installers (HVAC technicians). This measuring instrument allows for quick and efficient detection of HVAC problems.

Temperature and microampere measurement

The Fluke 116 Multimeter features advanced measurement functions, including temperature and microampere measurement ranges. This allows for accurate temperature measurement and detection of microamperes, which is essential for identifying HVAC problems.

Efficient and reliable

With the Fluke 116 Multimeter, you can perform measurements quickly and reliably. Thanks to its user-friendly interface and clear measurement results, you can work efficiently and make accurate diagnoses.

Useful features:

  • Digital multimeter designed specifically for HVAC professionals
  • Includes built-in thermometer to measure temperature from -40°C to z400°C (-40°F to 752°F)
  • Provides microamps to test flame sensors
  • Features low input impedance to helps prevent false readings due to ghost voltage
  • Presents a large white LED backlight for working in poorly lit areas
  • Measures resistance, continuity, frequency, and capacitance
  • Provides Min/Max/Average to record signal fluctuations
  • Comes with a holster with probe holders for easy storage
  • Features a compact ergonomic design for one-handed operation
  • Fits into optional ToolPak™ magnetic hanger for hands-free operation
  • CAT III 600 V safety rated"" For HVAC technicians, building maintenance

Includes:

  • 4 mm silicone test lead set
  • 80BK Integrated Temperature probe
  • Holster
  • Installed 9 V battery
  • User manual

Specifications: Fluke 116 HVAC Multimeter with Temperature and Microamps

Specifications
Maximum voltage between any terminal and earth ground 600 V
Safety IEC 61010-1: Pollution Degree 2
IEC 61010-2-033: CAT III 600V
Display Digital: 6,000 counts, updates 4 per second
Bar graph 33 segments, updates 32 per second
Operating temperature -10°C to + 50°C
Storage temperature -40°C to + 60°C
Battery type 9 volt Alkaline, IEC 6LR61
Battery life 400 hours typical, without backlight
Accuracy Specifications
DC millivolts Range/resolution 600.0 mV / 0.1 mV
Accuracy ±([% of reading] + [counts]): 0.5% + 2
DC volts Range/resolution 6.000 V / 0.001 V
60.00 V / 0.01 V
600.00 V / 0.1 V
Accuracy ±([% of reading] + [counts]): 0.5% + 2
Auto volts Range/resolution 600.0 V / 0.1 V
Accuracy 2.0% + 3 (DC, 45 Hz to 500 Hz)
4.0% + 3 (500 Hz to 1 kHz)
AC millivolts1 True RMS Range/resolution 600.0 mV / 0.1 mV
Accuracy 1.0% + 3 (DC, 45 Hz to 500 Hz)
2.0% + 3 (500 Hz to 1 kHz)
AC volts1 True RMS Range/resolution 6.000 V / 0.001 V
60.00 V / 0.01 V
600.0 V / 0.1 V
Accuracy 1.0% + 3 (DC, 45 Hz to 500 Hz)
2.0% + 3 (500 Hz to 1 kHz)
Continuity Range/resolution 600 Ω / 1 Ω
Accuracy Beeper on < 20 Ω, off > 250 Ω detects opens or shorts of
500 μs or longer.
Ohms Range/resolution 600.0 Ω / 0.1 Ω
6.000 kΩ / 0.001 kΩ
60.00 kΩ / 0.01 kΩ
600.0 kΩ / 0.1 kΩ
6.000 MΩ / 0.001 MΩ
Accuracy 0.9% + 1
Range/Resolution 40.00 MΩ / 0.01 MΩ
Accuracy 5% + 2
Diode Test Range/resolution 2.00 V / 0.001 V
Accuracy 0.9% + 2
Capacitance Range/resolution 1000 nF / 1 nF
10.00 μF / 0.01 μF
100.0 μF / 0.1 μF
9999 μF / 1 μF
100 μF to 1000 μF
Accuracy 1.9% + 2
Range/resolution > 1000 μF
Accuracy 5% + 20%
Lo-Z Capacitance Range 1 nF to 500 μF
Accuracy 10% + 2 typical
Temperature²
(Type-K thermocouple)
Range/resolution -40°C to 400°C / 0.1°C
Accuracy 1% + 10²
Range/resolution -40°F to 752°F / 0.2°F
Accuracy 1% + 18²
AC μA true-rms (45 Hz to 500 Hz) Range/resolution 600.0 μA / 0.1 μA
Accuracy 1.5% + 3
DC μamps Range/resolution 600.0 μA / 0.1 μA
Accuracy 1.0% + 2
Hz (V or A input)² Range/resolution 99.99 Hz / 0.01 Hz
999.9 Hz / 0.1 Hz
9.999 kHz / 0.001 Hz
50.00 kHz / 0.01 Hz
Accuracy 0.1% + 2
1. All AC voltage ranges except Auto-V/LoZ are specified from 1% to 100% of range. Auto-V/LoZ is specified from 0.0 V.
2. Temperature uncertainty (accuracy) does not include the error of the thermocouple probe.
3. Frequency is AC coupled, 5 Hz to 50 kHz for AC voltage. Frequency is DC coupled, 45 Hz to 5 kHz for AC current.
4. Temperature Range/Resolution: -40°F to 752°F / 0.2°F.
Mechanical and General Specifications
Size 167 x 84 x 46 mm (6.57 x 3.31 x 1.82 in)
Weight 550 g
Warranty 3 years
We found other products you might like!

* Ondanks een zeer uitgebreid stocksysteem, is het mogelijk dat de voorraadstatus niet overeenstemt met de actuele voorraad. Aarzel niet ons te contacteren, indien u zekerheid wenst over de beschikbaarheid.

** De weergegeven foto bij de producten kan verschillen van het eigenlijke product.